Journal Information
Vol. 16. Issue 4.
Pages 345-350 (July - August 2012)
Share
Share
Download PDF
More article options
Visits
3397
Vol. 16. Issue 4.
Pages 345-350 (July - August 2012)
Original article
Open Access
Autologous transplant: microbial contamination of hematopoietic stem cell products
Visits
3397
Igor Dullius Almeidaa, Tissiana Schmalfussb, Liane Marise Röhsigb, Luciano Zubaran Goldanic,
Corresponding author
lgoldani@ufrgs.br

Corresponding author at: Hospital de Clínicas de Porto Alegre, Section of Infectious Diseases, Rua Ramiro Barcelos, 2350, Porto Alegre, RS, 90035-003, Brazil.
a Hemotherapy Section, Hospital de Clínicas de Porto Alegre, Brazil
b Cryobiology Unit of Blood Umbilical Cord and Placental Bank, Hospital de Clínicas de Porto Alegre, Brazil
c Universidade Federal do Rio Grande do Sul, Infectious Diseases Section, Hospital de Clínicas de Porto Alegre, Brazil
This item has received

Under a Creative Commons license
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Figures (2)
Tables (4)
Table 1. Management considerations of HPCPB products with positive microbial cultures.
Table 2. Profile of underlying diseases and HPCPB collections performed at the Hemotherapy Section from 2000-2009.
Table 3. CD34+ count of contaminated and remaining stock HPCPB collections.*
Table 4. Antibiotic therapy of pre- and post-infusion of contaminated HPCPB.*
Show moreShow less
Abstract

Hematopoietic progenitor cells from peripheral blood (HPCPB) are commonly used for autologous and allogenic transplants in patients with most various onco-hematological diseases, and despite the utilization of sterile techniques during collection and processing of these products, bacterial contamination can occur. This study aimed to investigate the microbial contamination of HPCPB products. Microbial cultures of 837 HPCPB products between the year 2000 and 2009 were retrospectively analyzed to determine the incidence of culture positivity and identify the main organisms that cause contamination. The microbiological studies were performed with an automated system (BacT/Alert® bioMérieux Corporate). Thirty-six (4.3%) of 837 microbial cultures were contaminated. Coagulase-negative Staphylococcus was the most frequent bacteria isolated from HPCPB products (20 [56%] of the 36 positive microbial cultures). Considering the 36 contaminated samples, 22 HPCPB products were infused and 14 discarded. Pre- and post-infusion antibiotic therapy of the patients transfused with contaminated products was established based on the isolated microorganism and its antibiogram. Microbial contamination rate of HPCPB products was low. Clinically significant outcomes after infusion of contaminated HPCPB products were not observed.

Keywords:
Autologous transplant
Hematopoietic stem cell products
Microbial contamination
Quality control
Bacterial contamination
Full Text
Introduction

Hematopoietic progenitor cells from peripheral blood (HPCPB) are commonly used for autologous and allogenic transplants in patients with various onco-hematological diseases. The progenitor hematopoietic cells are capable of self-renewal and differentiation in all blood cells lineages. Bone marrow is the traditional source for obtaining HPCPB, collected by multiple punctures and aspirations of the posterior iliac crests. The aspirated material contains red blood cells, leukocytes, platelets, mast cells, plasma, and pluripotent hematopoietic progenitor cells. In recent years, the collection of HPCPB via apheresis has been increasingly used. The combination of high doses of chemotherapy with subsequent transplantation of these cells constitutes the standard treatment for many onco-hematological diseases.

Obtaining, processing, storing and transplantation of HPCPB involve many steps, which are normally performed in different environments and may result in microbial contamination. In fact, HPCPB manipulation during processing and pre- and post-cryopreservation are important sources of bacterial contamination of these cells.1 The donor may be the source of microbial contamination of HPCPB. Donors with asymptomatic bacteremia or who are recovering from a bacterial infection may develop episodes of transient bacteremia, which can lead to product contamination. In addition, HPCPB collected by apheresis often requires the insertion of central venous catheters (CVC). Infections associated with CVCs are an important source of transient bacteremia and a possible cause of HPCPB contamination.2

Thus, in order to ensure a final product appropriate for transplant, it is essential to adhere to a quality control policy. Such controls should include CD34+cell count, cell viability assessment, and microbiological monitoring.3

The main objective of this study was to investigate the incidence of positive microbial cultures for HPCPB products from donors attending a tertiary care hospital in the period from 2000 to 2009. In parallel, the major bacteria contaminating HPCPB products and the pre- and post-infusion antibiotic therapy for the contaminated cells were also described. In addition, the blood culture results after thawing the bag containing HPCPB, which were infused or discarded according to medical decision, were also analyzed (Table 1).

Table 1.

Management considerations of HPCPB products with positive microbial cultures.

Administer the product  Discard the product 
Slow growing organism*  Rapidly growing organism 
Skin or environmental contaminant  Enteric or pathogenic organism 
Donor or patient is not available for recollection  Product can easily be replaced 
New product requires remobilization or central line placement  Patient can tolerate delay and recollection 
Product contains majority of total cell dose  Product contains small percentage of total cell dose 

HPCPB, hematopoietic progenitor cells from peripheral blood.

*

Culture positivity beyond 30hours of incubation.

Material and methods

Microbial cultures of 837 HPCPB products of donors attending a tertiary care hospital located in southern Brazil from 2000 to 2009 were retrospectively analyzed to determine the incidence of microbial culture positivity and identification of the main organisms causing contamination. In addition, the charts of the donors with positive HPCPB microbial cultures were reviewed.

For the sterility control of the HPCPB products, after the cryopreservation process and before freezing, 3mL samples of the product were inoculated in pediatric blood culture bottles with 20mL of activated charcoal (BacT/Alert® bioMérieux Corporate–Durham, USA). In addition, after blood bag thawing, samples were collected for microbial cultures at the moment of the infusion. Such action serves to verify a possible contamination at the time of water-bath defrosting. Cultures were sent to the microbiology department, where they were incubated for five days. When positive, microscopy and bacterial isolation were performed and identified through standard biochemical tests.

Data were organized and analyzed using the Microsoft Excel 2007® software, according to the distribution of frequency.

Microbiological surveys were performed with automated BacT/Alert® at 36°C. The products were added into a class I laminar-flow cabinet with HEPA filters.

The study was approved by the local ethics committee, which is accredited by the National Committee of Ethics in Research of the National Health Department and the Office for Human Research Protection (OHRP) of the United States.

Results

A total of 837 HPCPB collections and microbial cultures were performed at the hemotherapy section from 2000 to 2009. The average volume drawn and time for collection and processing were 255mL and 206minutes respectively. The underlying diseases and the main characteristics of the patients that received HPCPB products are presented in Table 2. The main underlying diseases included multiple myeloma (n=314), followed by Hodgkin lymphoma (n=143), non-Hodgkin lymphoma (n=132), acute myeloid leukemia (n=63), neuroblastoma (n=52), Wilms tumor (n=28), meduloblastoma (n=23), and Ewing sarcoma (n=16).Thirty-six of the 837 collected samples (4.3%) yielded positive cultures for bacteria. Fig. 1 presents the annual contamination rate of the HPCPB products from 2000 to 2009. As shown in Fig. 2, the most frequently isolated organism was coagulase-negative Staphylococcus (56%), followed by Staphylococcus aureus (17%), Bacillus sp. (8%), coryneform Gram-positive bacilli (8%), non-coryneform Gram-positive bacilli (6%), Enterobacter sp. (3%), and Citrobacter freundii (3%). Coagulase-negative Staphylococcus isolates were 100% resistant to beta-lactams antibiotics including oxacillin.

Table 2.

Profile of underlying diseases and HPCPB collections performed at the Hemotherapy Section from 2000-2009.

Underlying disease  n (collections)  Age (average)  Gender
     
Amiloydosis  58 
Erythroid series aplasia  – 
Pleuropulmonary blastoma  – 
CNS germinoma  13  – 
Immunocytoma  40  – 
Acute lymphoblastic leukemia  17  – 
Acute lymphoide leukemia  20 
Acute myeloid leukemia  63  31  47  16 
Chronic myeloid leukemia  42  – 
T-cell lymphoma  32  – 
Hodgkin lymphoma  143  26  59  84 
Mantle-cell lymphoma  57  – 
B-cell granulocytic lymphoma  41  – 
T cell lymphoblastic lymphoma  34  – 
Non-Hodgkin lymphoma  132  43  82  50 
Peripheral T lymphoma  33  – 
Medulloblastoma  23  12  18 
Myelophibrosis  45  – 
Multiple myeloma  314  54  170  144 
Tumor of suprarenal gland  – 
Thoracic malignant neoplasm  – 
Malignant neoplasm of kidney and renal pelvis  – 
Neuroblastoma  52  41  11 
Pancreatoblastoma  15  – 
Pineoblastoma  – 
Retinoblastoma 
Renal cell sarcoma  – 
Ewing sarcoma  16  13  11 
Wilms sarcoma  11  – 
Poems syndrome+Castleman disease  50  – 
Askin tumor  16 
Renal cell tumor  – 
Ewing tumor  11  – 
Ovarium tumor  12  – 
Endodhermal sinus tumor  15 
Testicle tumor  28  – 
Wilms tumor  28  12  16 
Germinative tumor  18  – 
Total  837    470  367 
Fig. 1.

Annual rate of contamination in samples collected in the period from 2000 to 2009. Distribution of the 36 contaminated samples of total 837 made in this period.

(0.1MB).
Fig. 2.

Bacteria isolated in the 36 contaminated hematopoietic progenitor cells from peripheral blood products.

(0.08MB).

Twenty-two of the 36 HPCPB products with positive microbial cultures were infused. and 14 were discarded based on the medical staff's decision. Considering that HPCPB products contamination has an impact in reducing the number of CD34+ cells, and therefore reducing hematopoietic engraftment after peripheral blood stem cell transplantation, Table 3 presents the CD34+ counts of the discarded contaminated HPCPB collections and the remaining stock collections for each patient.

Table 3.

CD34+ count of contaminated and remaining stock HPCPB collections.*

Donor-bacteria  nX106CD34/Kg (discarded collection)  nX106CD34/Kg (remaining stock collections) 
1- Citrobacter freundii  0.35  1.43 
2- Staphylococcus coagulase neg.  0.13  0.29 
3- Staphylococcus coagulase neg.  3.21  3.33 
3- Staphylococcus aureus     
3- Staphylococcus aureus     
3- Staphylococcus aureus     
3- Staphylococcus coagulase neg.     
4- Staphylococcus aureus  1.67  2.56 
5- Staphylococcus aureus  0.32  1.39 
6- Staphylococcus coagulase neg.  3.2  7.61 
7- Staphylococcus aureus  1.01  4.11 
8- Coryneform Gram+ bacilli  1.33 
8- Coryneform Gram+ bacilli     
9- Staphylococcus coagulase Neg.  1.27  3.14 

HPCPB, hematopoietic progenitor cells from peripheral blood.

HPCPB, hematopoietic progenitor cells from peripheral blood; M, masculine; F, feminine; CNS, central nervous system.

*

Total of 14 discarded collections; each number represents a patient; patients 3 and 8 had more than one collection.

Table 4 presents pre-infusion and post-infusion antibiotic therapy of the patients transfused with contaminated products. Although nine of the 22 infusions had not received antimicrobial therapy prior to the infusion of HPCPB products, all of the patients received such therapy during or after the HPCPB infusion.

Table 4.

Antibiotic therapy of pre- and post-infusion of contaminated HPCPB.*

Bacterium  Pre-infusion  Post-infusion 
1- Non-coryneform Gram+bacilli  Non-administered  Norfloxacin 
2- Staphylococcus coagulase neg.  Non-administered  Ampicillin+cefepime 
3- Bacillus sp.  Ciprofloxacin  Vancomycin+ciprofloxacin 
4- Staphylococcus coagulase neg.  Sulfa+trimethoprim  Vancomycin 
5- Enterobacter sp.  Norfloxacin+sulfa+trimethoprim  Cefepime 
6- Staphylococcus coagulase neg.  Non-administered  Gentamicin+cefepime 
7- Staphylococcus coagulase neg.  Non-administered  Vancomycin+cefepime 
8- Bacillus Gram+ coryneform  Ciprofloxacin  Vancomycin+cefepime 
9- Staphylococcus coagulase neg.  Clindamycin  Cefepime+amikacina 
10- Staphylococcus coagulase neg.  Ciprofloxacin  Oxacilin+cefepime 
11- Staphylococcus coagulase neg.  Oxacillin  Vancomycin+cefepime 
12- Bacillus sp.  Cefepime  Amikacin 
13- Bacillus sp.  Non-administered  Vancomycin+cefepime 
14- Staphylococcus coagulase neg.  Clindamycin  Clindamycin 
15- Staphylococcus coagulase neg.  Non-administered  Oxacillin+cefepime 
16- Staphylococcus coagulase neg.  Clindamycin  Cefepime+oxacilin 
17- Staphylococcus coagulase neg.  Sulfa+trimethoprim  Vancomycin 
17- Staphylococcus coagulase neg.  Sulfa+trimethoprim  Vancomycin 
18- Staphylococcus coagulase neg.  Non-administered  Cefepime+clindamycin 
19- Staphylococcus coagulase neg.  Oxacillin  Cefepime 
20- Staphylococcus coagulase neg.  Non-administered  Cefepime+vancomycin 
21- Non-coryneform Gram+ bacilli  Non-administered  Cefepime 

HPCPB, hematopoietic progenitor cells from peripheral blood.

*

The above contaminated infusions were performed in different patients, except nr. 17.

Twelve (55%) of the 22 contaminated HPCPB products presented positive microbial cultures after the freeze-thaw process, whereas in the remaining products (45%) the cultures were negative.

Discussion

Similar to the present results, previous studies have reported microbial contamination rates varying from 1.6% a 4.5%.4–8 The incidence of microbial contamination of HPCPB products in those studies varied according to the source of the cells. Kamble et al.5 have shown contamination in four of the 26 collections (15%) from core blood, eight of 177 (4.5%) from bone marrow, and 21 of 532 (3.9%) from peripheral blood. Coagulase-negative Staphylococcus was the organism predominantly isolated in this study, with 20 (56%) of the 36 positive microbial cultures. Most of the previous studies also identified the coagulase-negative Staphylococcus and other bacteria that often colonize the skin and are water contaminants.9–12 The potential contamination sources of HPCPB products include reagents, venous access-catheters, aseptic failure, cell processing, bag disruption, equipment used for water-bath, incubators, and centrifuges.13–17

Even though contaminated HPCPB products are often discarded, 22 of the 36 contaminated collections were infused. Authors have reported success achieved after the infusion of the contaminated HPCPB products, with few clinical consequences.9,18 In fact, contaminated HPCB products should not be automatically discarded because, when administered with specific precautions, they do not have either adverse effects or significant sequelae. As shown in Table 1, specific measurements should be considered when deciding to discard or administer the product.19

CD34+ cell dose is correlated with both early engraftment kinetics and late peripheral blood counts. A threshold effect between rapid and slow engraftment occurred at 5×106 CD34+ cells/kg. In addition, hemoglobin and platelets were significantly higher at 180, 360, and 540 days after transplantation for those patients who received >5×106 CD34+ cells/kg. Therefore, for autologous transplantations, a dose higher than CD34+ cell appears to be correlated with improved long-term hematopoiesis. In this study, most of the contaminated collections presented low CD34+ cell dose. Despite contamination, some frozen stocks of those collections from these patients presented high CD34+ cell dose, which could be successfully used in further HCPBC transplants.

Contamination of HPCPB products with clinically significant adverse outcome occurs especially with potentially pathogenic bacteria, but is rare, with an incidence of 0.3% of notified cases.5 Klein et al.20 have reported a patient that died due to multi-organ-system failure, after having received HPCPB product contaminated with Burkholderia cepacia, even though the infusion was initiated with proper antimicrobial therapy. Moreover, contaminated HPCPB products with methicillin-resistant Staphylococcus aureus have been shown to cause severely disseminated infection in patients.5 Interestingly, bacterial contamination of those products does not affect the patients’ transplant kinetics. It was previously demonstrated by Schwella et al.12 that there was no significant differences in hematopoietic recovery time, duration of fever, and number of days of antimicrobial administration in patients who had received contaminated HPCPB products when compared with those who had received products free of contamination.12 In fact, previous studies have shown that most patients successfully receive an HPCPB product with prophylactic antibiotic therapy before infusion of the contaminated product based on the isolated organism, sensitivity to antimicrobial agents and urgency for the transplant.20 This decision varies in different centers. For instance, Kamble et al.5 have reported that prophylaxis is unnecessary, because most of the contaminations are caused by non-pathogenic bacteria and their infusions rarely cause bacteremia or septicemia. Interestingly, some patients infused with collections contaminated with coagulase-negative Staphylococcus that were treated with inappropriate prophylactic antibiotics such as oxacillin and ciprofloxacin did not present any unfavorable outcome.

In the present study approximately 50% of the HPCPB collections were found to persist contaminated after the freeze-thaw process. One of the reasons for this finding could be the contamination of HPCPB products with a low number of colony forming units of bacteria. In addition, cryoprotectors used in HPCPB products, such as the organosulfur compound dimethyl sulfoxide (DMSO), have potent bactericidal properties against Gram-positive and Gram-negative bacteria.19 Kipp et al.6 have shown that the CFUs of different bacteria diminished after the cryopreservation process. For instance, the CFU of Staphylococcus epidermidis, decreased approximately 13.7% after addition of DMSO. Moreover, the presence of active phagocytic cells in the frozen products could additionally eliminate existing bacteria.6 On the other hand, Gram-positive bacteria such as Staphylococcus sp. are known to survive after the cryopreservation process.5 Different studies have shown conflicting results regarding the survival of coagulase-negative Staphylococcus after the cryopreservation process.9,12,16

Data have shown that aseptic conditions impact bacterial contamination in areas where HPCPB products are handled and processed. There is a 5.2% decrease in HPCPB products contamination at a clean bench compared with 0.8% decrease at a bench in laboratory implementing good manufacturing practices with certified conditions.11 Thus, quality control and good practices of handling and conservation of reagents and equipment used in cell cryopreservation are essential to provide safer products for patients, with reduction of the probable contamination sources.21

In summary, our study has shown that the contamination rate of HPCPB products is overall low and it is usually caused by the normal skin microbiota, which could survive the cryopreservation process. No clinically significant outcomes were observed in patients transfused with contaminated HPCPB products. Continuous monitoring of HPCPB products is essential to assure the success of the transplantation.

Conflict of interest

All authors declare to have no conflict of interest.

References
[1]
Z. Hirji, R. Saragosa, H. Dedier, et al.
Contamination of bone marrow products with an actinomycete resembling Microbacterium species and reinfusion into autologous stem cell and bone marrow transplant recipients.
Clin Infect Dis, 36 (2003), pp. 115-121
[2]
F.A. Naoum, L.T.V. Martins, N.S. Castro, J.C. Barros, C.S. Chiattone.
Perfil microbiológico dos pacientes nos primeiros trinta dias após transplante de medula óssea do Serviço de Transplantes da Santa Casa de São Paulo.
Rev Bras Hematol Hemoter, 24 (2002), pp. 91-96
[3]
L. Larrea, J. de la Rubia, M.A. Soler, et al.
Quality control of bacterial contamination in autologous peripheral blood stem cells for transplantation.
Haematologica, 89 (2004), pp. 1232-1237
[4]
G. Aksu, M.Z. Ruhi, H. Akan, et al.
Aerobic bacterial and fungal infections in peripheral blood stem cell transplants.
Bone Marrow Transplant, 27 (2001), pp. 201-205
[5]
R. Kamble, S. Pant, G.B. Selby, et al.
Microbial contamination of hematopoietic progenitor cell grafts-incidence, clinical outcome, and cost-effectiveness: an analysis of 735 grafts.
Transfusion, 45 (2005), pp. 874-878
[6]
F. Kipp, E. Linnemann, R.J. Fischer, W. Sibrowski, U. Cassens.
Cryopreservation reduces the concentration of detectable bacteria in contaminated peripheral blood progenitor cell products.
Transfusion, 44 (2004), pp. 1098-1103
[7]
P.A. Patah, S. Parmar, J. McMannis, et al.
Microbial contamination of hematopoietic progenitor cell products: clinical outcome.
Bone Marrow Transplantation, 40 (2007), pp. 365-368
[8]
J.N. Lowder, P. Whelton.
Microbial contamination of cellular products for hematolymphoid transplantation therapy: assessment of the problem and strategies to minimize the clinical impact.
Cytother, 5 (2003), pp. 377-390
[9]
H.K. Jestice, M. Farrington, C. Hunt, et al.
Bacterial contamination of peripheral blood progenitor cells for transplantation.
Transfus Med, 6 (1996), pp. 103-110
[10]
D. Padley, F. Koontz, M.E. Trigg, R. Gingrich, R.G. Strauss.
Bacterial contamination rates following processing of bone marrow and peripheral blood progenitor cell preparations.
Transfusion, 36 (1996), pp. 53-56
[11]
M. Ritter, J. Schwedler, J. Beyer, et al.
Bacterial contamination of ex vivo processed PBPC products under clean room conditions.
Transfusion, 43 (2003), pp. 1587-1595
[12]
N. Schwella, O. Rick, H.G. Heuft, et al.
Bacterial contamination of autologous bone marrow: reinfusion of culture-positive grafts does not result in clinical sequelae during the posttransplantation course.
Vox Sang, 74 (1998), pp. 88-94
[13]
U. Cassens, C. Ahlke, H. Garritsen, et al.
Processing of peripheral blood progenitor cell components in improved clean areas does not reduce the rate of microbial contamination.
Transfusion, 42 (2002), pp. 10-17
[14]
T.P. Nifong, C. Ehmann, J.A. Mierski, R.E. Domen, W.B. Rybka.
Favorable outcome after infusion of coagulase-negative Staphylococci- contaminated peripheral blood hematopoietic cells for autologous transplantation.
Arch Pathol Lab Med, 127 (2003), pp. e19-e21
[15]
D.J. Padley, C.W. Greiner, T.L. Heddlesten-Rediske, M.K. Hopkins, M.L. Maas, D.A. Gastineau.
Endogenous microbial contamination of cultured autologous preparations in trials of cancer immunotherapy.
Cytotherapy, 5 (2003), pp. 147-152
[16]
H.M. Prince, S.R. Page, A. Keating, et al.
Microbial contamination of harvested bone marrow and peripheral blood.
Bone Marrow Transplant, 15 (1995), pp. 87-91
[17]
I.J. Webb, P.S. Coral, J.W. Andersen.
Sources and sequeale of bacterial contamination of hematopoietic stem cell components: implications for the safety of hematotherapy and graft engineering.
Transfusion, 36 (1996), pp. 782-788
[18]
R.M. Nasser, I. Hajjar, L.M. Sandhaus, et al.
Routine cultures of bone marrow and peripheral stem cell harvests: clinical impact, cost analysis, and review.
Clin Infect Dis, 27 (1998), pp. 886-888
[19]
D.J. Padley, A.B. Dietz, D.A. Gastineau.
Sterility testing of hematopoietic progenitor cell products: a single-institution series of culture-positive rates and successful infusion of culture-positive products.
Transfusion, 47 (2007), pp. 636-643
[20]
M.A. Klein, D. Kadidlo, J. McCullough, D.H. McKenna, L.F. Burns.
Microbial contamination of hematopoietic stem cell products: Incidence and clinical sequelae.
Biol Blood and Marrow Transplant, 12 (2006), pp. 1142-1149
[21]
L. Mele, F.M. Dallavalle, G. Verri, et al.
Safety control of peripheral blood progenitor cell processing- eight year-survey of microbiological contamination and bag ruptures in a single institution.
Transfus Apher Sci, 33 (2005), pp. 269-274
Copyright © 2012. Elsevier Editora Ltda.. All rights reserved
The Brazilian Journal of Infectious Diseases
Article options
Tools